Retinal and Glaucoma Equipment

Testing the progression of retinal disease and glaucoma can be quite challenging. To ensure accuracy, it is prudent to perform a variety of tests on the patient. That is why the Clearview Institute has invested in a wide range of leading retinal and glaucoma diagnostic equipment to help us assess your condition and follow it over time.

Visante™ OCT

Manufactured by Carl Zeiss, the Visante Optical Coherence Technology (OCT) allows us to get a cross-section of your eye using a non-harmful, no-touch laser. A precise glaucoma measurement tool, it determines the thickness of the cornea and gives us an immediate picture of what is going on from the beginning of the cornea to the beginning of the lens.

Cirrus™ High Definition OCT

Manufactured by Carl Zeiss, this non-invasive piece of equipment looks at the retina at the back part of the eye as well as the optic nerve. It gives a baseline for what the nerve is like down to the microns and helps us determine whether the nerve has a problem. It can also reveal whether there is fluid or swelling beneath the retina.

Heidelberg Retinal Tomography (HRT)

An excellent way to track changes in glaucoma patients, the HRT helps us determine what stage of progression they are in. Its confocal laser scanning system provides detailed three-dimensional images of the posterior segment of the eye, making it effective for diagnosing conditions such as nerve fiber defects.

GDx™VCC

Manufactured by Carl Zeiss, this important tool is generally used for early detection of glaucoma. But it may also be used for ongoing assessment. It utilizes a laser polarmeter to detect changes in the optic nerve and lets doctors evaluate glaucomatous changes over time and adjust the patient's management plan as needed.

Humphrey Field Analyzer®

Manufactured by Carl Zeiss, the Humphrey Field Analyzer is used for glaucoma management and blindness prevention. It accurately determines the stage of disease, rate of progression and a patient's risk of future vision loss by automatically summarizing all available visual field test results on a single page and by calculating each patient's rate of visual field deterioration.

Reichert Ocular Response Analyzer

Manufactured by Reichert Ophthalmic, the Reichert Ocular Response Analyzer provides a new measurement of corneal tissue properties called Corneal Hysteresis (CH) that is a result of viscous damping in the corneal tissues. This measurement helps us screen out patients who would be at risk for complications from laser refractive surgery as well as those who are more likely to develop glaucoma.